3-Ph 3-Level Zvs Dc-Dc Converter
Abstract
This paper proposes development of soft switching scheme for three phase three level DC-DC converter for different duty cycles to achieve ZVS for all switches. The ZVS is achieved with output inductor and leakage inductor of transformer. This paper describes the main operational modes of proposed converter for different duty cycle and simulation results are observed and compare the switching losses of proposed converter with and without ZVS.
KEYWORDS—Zero Voltage Switching (ZVS), Three Phase Three Level (TPTL),DC-DC converter ,Pulse width modulation ,Duty cycle ,Soft switching.
Full Text:
PDFCopyright (c) 2018 Edupedia Publications Pvt Ltd

This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
All published Articles are Open Access at https://journals.pen2print.org/index.php/ijr/
Paper submission: ijr@pen2print.org