Improved Design Presaging Govern For 3-Segment Inverter With Gain LC Filter Out

Balla Aravind Kumar, M.V. Praveen Reddy, M. Ramesh

Abstract


Three-phase inverters with an output LC filter are commonly used to provide sinusoidal voltages with low-harmonic distortion. Constraint on peak filter current is often desirable to protect the components from potential damage. In case of constraints, implicit and explicit model-predictive control (MPC) are some of the feasible controller options. The conventional implicit MPC requires a large number of computations, whereas explicit MPC cannot directly incorporate real-time changes in model parameters, while still being computationally expensive than some of the other control schemes, e.g., hysteresis, dead beat control, etc. In this paper, we propose a new approach to solve the optimization problem in implicit MPC that has a computational complexity approximately five times less than that of explicit MPC.We have been able to achieve lower computational requirements by exploiting the inverter model and the structure of constraints.


Full Text:

PDF




Copyright (c) 2017 Edupedia Publications Pvt Ltd

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

 

All published Articles are Open Access at  https://journals.pen2print.org/index.php/ijr/ 


Paper submission: ijr@pen2print.org